ISR with AC power, 2FE, 4 Interface Card Slots, 2 PVDM slots, 2 AIMs, and Cisco IOS IP Base Software
CISCO2801 Router - Key Features of the Cisco 2801 Integrated Services Router:
Mid/High-Density, High Performance Services
Security: On-board encryption, up to 800 VPN tunnels (AIM); IOS FW, NAC, IPS, or Content Security
Voice: Mid/High-density analog/digital voice with IP Telephony, Voice Mail; CallManager Express or Survivable Remote Site Telephony support for up to 24 IP phones
High-performance concurrent security, voice and advanced services to multiple T1/E1 WAN rates
Integrated Dual 10/100 ports
Optional integration of L2 switching with PoE
Enhanced Modularity and Investment Protection
Flexible expansion ( 2 HWIC slots), additional concurrent services
Existing WIC/VIC/VWIC, AIM support
Scalable services deployment and availability features
Product Architecture:

DRAM
Default: 128 MB
Maximum: 384 MB
Compact Flash
Default: 64 MB
Maximum: 128MB
Fixed USB 1.1 Ports: 1
Onboard LAN Ports: 2-10/100
Onboard AIM (Internal) Slot: 2
Interface Card Slots
4 slots; 2 slots, support HWIC, WIC, VIC, or VWIC, type modules
1 slot supports WIC,VIC, or VWIC type, modules
1 slot supports VIC or VWIC type modules
PVDM (DSP) Slots on Motherboard: 2
With Integrated Hardware-Based Encryption
VPN Hardware Acceleration (on Motherboard): DES, 3DES, AES 128, AES 192, and AES 256
Optional Integrated In-Line Power (POE): Yes, requires AC-IP power supply
Console Port (up to 115.2kbps):2
Auxiliary Port(up to 115.2 kbps):1
Minimum Cisco IOS Software Release: 12.3(8)T
Rack Mounting: Yes, 19-inch

Power Requirements:

AC Input Voltage: 1 00 to 240 VAC, autoranging
AC Input Frequency: 47-63 Hz
AC Input Current: 2A (110V) 1A (230V)
AC Input Surge Current: 50A maximum, one cycle (-48V power included)
AC-IP Maximum In-Line Power Distribution: 120W
AC-IP Input Current: 4A (110V) 2A (230V) 8A (110V) 4A (230V)
AC-IP Input Surge Current: 50A maximum, one cycle (-48V power included)
DC Input Voltage: No DC Power Option available
DC Input Current: No DC Power Option available
Typical Power Dissipation (No Modules): 42W (143 BTU/hr)
Power Dissipation-AC without IP Phone Support: 150W (511 BTU/hr)
Power Dissipation-AC with IP Phone Support-System Only: 150W (511 BTU/hr)
Power Dissipation-AC with IP Phone Support-IP Phones: 180W (612 BTU/hr)
Power Dissipation-DC: Not applicable
RPS: No
Recommended RPS Unit: No RPS option

Environmental Specifications

Operating Temperature: 32° to 104°F (0° to 40°C)
Non-Operating Temperature: -4° to 149°F (-20° to 65°C)
Maximum Operating Temperature at Altitude
40°C @ sea level
31°C @ 6,000 ft (1800 m)
25°C @ 10,000 ft (3000 m)
Note: Derate 1.5°C per 1000 ft
Operating Humidity: 10 to 85% non-condensing
Dimensions (H x W x D)
1.72 x 17.5 x 16.5in.
(43.7 x 445 x 419mm)
Rack Height: 1 rack unit (1RU)
Weight (Fully Configured): 13.7 lb (6.2 kg)
Noise Level (Min/Max)
39 dBA for normal operating temperature (<90°F/32.2°C)
53.5 dBA (@ maximum fan speed)
Regulatory Compliance
NEBS: No
Safety
UL 60950
CAN/CSA C22.2 No. 60950
IEC 60950
EN 60950-1
AS/NZS 60950
Immunity
EN300386
EN55024/CISPR24
EN50082-1
EN61000-6-2
EMC
FCC Part 15
ICES-003 Class A
EN55022 Class A
CISPR22 Class A
AS/NZS 3548 Class A
VCCI Class A
EN 300386
EN61000-3-3
EN61000-3-2
FIPS-2: FIPS 140-2 Certification for 2801, 2811, 2821, 2851